When UL RX_LEV Upper Threshold is modified, the BSC simultaneously modifies AMR UL RX_LEV Upper Threshold and UL Expected Level at HO Access accordingly.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning:Index Type Value range:BYNAME(By Name),BYIDX(By Index) Explanation: Index Type. Default value:None |
CELLIDX | Cell Index | Meaning:Cell Index Value range:0~2047 Explanation: This parameter indicates the source cell index. The source cell index must be unique. Default value:None |
CELLNAME | Cell Name | Meaning:Cell Name Value range:1-32 characters Explanation: This parameter indicates the name of the source cell. The name of each cell under one BSC must be unique. Default value:None |
PCADJPERIOD | PC Interval | Meaning:PC Interval Value range:1~15 Explanation:This parameter specifies the minimum time interval between two continuous power control commands. Default value:None |
ULSSHIGHTHRED | UL RX_LEV Upper Threshold | Meaning:UL RX_LEV Upper Threshold Value range:0~63 Explanation:The power control step is calculated based on the signal level. The signal level has an upper threshold and a lower threshold. Power control is not performed if the signal level is between the upper threshold and the lower threshold. Power control is performed only when the signal level exceeds the upper threshold or is below the lower threshold. The level values 0 through 63 map to -110 dBm to -47 dBm. Default value:None |
ULSSLOWTHRED | UL RX_LEV Lower Threshold | Meaning:UL RX_LEV Lower Threshold Value range:0~63 Explanation:The power control step is calculated based on the signal level. The signal level has an upper threshold and a lower threshold. Power control is not performed if the signal level is between the upper threshold and the lower threshold. Power control is performed only when the signal level exceeds the upper threshold or is below the lower threshold. The level values 0 through 63 map to -110 dBm to -47 dBm. Default value:None |
ULQHIGHTHRED | UL Qual. Upper Threshold | Meaning:UL Qual. Upper Threshold Value range:0~7 Explanation:When the power control step is calculated based on the signal quality, the upper threshold and the lower threshold of the quality zone are set. When the signal quality exceeds the upper threshold or is below the lower threshold, power control is performed. This parameter specifies the upper threshold of the uplink quality for power control. The mapping between the BER and the quality level is as follows: Level 0: BER smaller than 0.2% Level 1: BER ranges from 0.2% to 0.4% Level 2: BER ranges from 0.4% to 0.8% Level 3: BER ranges from 0.8% to 1.6% Level 4: BER ranges from 1.6% to 3.2% Level 5: BER ranges from 3.2% to 6.4% Level 6: BER ranges from 6.4% to 12.8% Level 7: BER greater than 12.8%. Default value:None |
ULQLOWTHRED | UL Qual. Lower Threshold | Meaning:UL Qual. Lower Threshold Value range:0~7 Explanation:When the power control step is calculated based on the signal quality, the upper threshold and the lower threshold of the quality zone are set. When the signal quality exceeds the upper threshold or is below the lower threshold, power control is performed. This parameter specifies the lower threshold of the uplink quality for power control. The mapping between the BER and the quality level is as follows: Level 0: BER smaller than 0.2% Level 1: BER ranges from 0.2% to 0.4% Level 2: BER ranges from 0.4% to 0.8% Level 3: BER ranges from 0.8% to 1.6% Level 4: BER ranges from 1.6% to 3.2% Level 5: BER ranges from 3.2% to 6.4% Level 6: BER ranges from 6.4% to 12.8% Level 7: BER greater than 12.8%. Default value:None |
DLSSHIGHTHRED | DL RX_LEV Upper Threshold | Meaning:DL RX_LEV Upper Threshold Value range:0~63 Explanation:The power control step is calculated based on the signal level. The signal level has an upper threshold and a lower threshold. Power control is not performed if the signal level is between the upper threshold and the lower threshold. Power control is performed only when the signal level exceeds the upper threshold or is below the lower threshold. The level values 0 through 63 map to -110 dBm to -47 dBm. Default value:None |
DLSSLOWTHRED | DL RX_LEV Lower Threshold | Meaning:DL RX_LEV Lower Threshold Value range:0~63 Explanation:The power control step is calculated based on the signal level. The signal level has an upper threshold and a lower threshold. Power control is not performed if the signal level is between the upper threshold and the lower threshold. Power control is performed only when the signal level exceeds the upper threshold or is below the lower threshold. The level values 0 through 63 map to -110 dBm to -47 dBm. Default value:None |
DLQHIGHTHRED | DL Qual. Upper Threshold | Meaning:DL Qual. Upper Threshold Value range:0~7 Explanation:When the power control step is calculated based on the signal quality, the upper threshold and the lower threshold of the quality zone are set. When the signal quality exceeds the upper threshold or is below the lower threshold, power control is performed. This parameter specifies the upper threshold of the downlink quality for power control. The mapping between the BER and the quality level is as follows: Level 0: BER smaller than 0.2% Level 1: BER ranges from 0.2% to 0.4% Level 2: BER ranges from 0.4% to 0.8% Level 3: BER ranges from 0.8% to 1.6% Level 4: BER ranges from 1.6% to 3.2% Level 5: BER ranges from 3.2% to 6.4% Level 6: BER ranges from 6.4% to 12.8% Level 7: BER greater than 12.8%. Default value:None |
DLQLOWTHRED | DL Qual. Lower Threshold | Meaning:DL Qual. Lower Threshold Value range:0~7 Explanation:When the power control step is calculated based on the signal quality, the upper threshold and the lower threshold of the quality zone are set. When the signal quality exceeds the upper threshold or is below the lower threshold, power control is performed. This parameter specifies the lower threshold of the downlink quality for power control. The mapping between the BER and the quality level is as follows: Level 0: BER smaller than 0.2% Level 1: BER ranges from 0.2% to 0.4% Level 2: BER ranges from 0.4% to 0.8% Level 3: BER ranges from 0.8% to 1.6% Level 4: BER ranges from 1.6% to 3.2% Level 5: BER ranges from 3.2% to 6.4% Level 6: BER ranges from 6.4% to 12.8% Level 7: BER greater than 12.8%. Default value:None |
PWRCTRLSW | Power Control Switch | Meaning:Power Control Switch Value range:HW2(HW2 Power Control),HW3(HW3 Power Control) Explanation:This parameter specifies whether enable Huawei II power control algorithm or Huawei III power control algorithm. Default value:None |
AMRSADLUPGRADE | AMR SACCH Downlink Power Upgrade | Meaning:AMR SACCH Downlink Power Upgrade Value range:0~15 Explanation:This parameter is configured for SACCH power control. When the DSP sends SACCH frames, the power control level is raised by N according to this configuration. Default value:None |
PWRBCDALLOWD | Power Forecast Allowed | Meaning:Power Forecast Allowed Value range:NO(NO),YES(YES),INVALID(INVALID) Explanation:This parameter specifies whether to allow active power control, that is, power forecast. Default value:None |
COMBINERLOSS | Combiner Loss | Meaning:Combiner Loss Value range:0~100 Explanation:This parameter is used to evaluate the downlink power in assignment procedure. The Combiner Loss is proportional to the downlink power. Default value:None |
DOUBLEANTENNAGAIN | Double Antenna Gain | Meaning:Double Antenna Gain Value range:0~255 Explanation:This parameter is used to evaluate the downlink power in assignment procedure. The Double Antenna Gain is proportional to the downlink power. Default value:None |
PATHLOSS | Path Loss of Different Frequency Band | Meaning:Path Loss of Different Frequency Band Value range:0~255 Explanation:This parameter determines the pass loss difference between frequency bands. Default value:None |
EXPDLRXLEV | Expected DL RX_LEV | Meaning:Expected DL RX_LEV Value range:0~63 Explanation:This parameter specifies the expected strength of signals transmitted by the BTS and received by the MS in power forecast. This parameter is used to calculate the initial transmit power of the BTS. Default value:None |
EXPULRXLEV | Expected UL RX_LEV | Meaning:Expected UL RX_LEV Value range:0~63 Explanation:This parameter specifies the expected strength of signals transmitted by the MS and received by the BTS in power forecast. This parameter is used to calculate the initial transmit power of the MS. Default value:None |
SAICALLOWED | Saic Allowed | Meaning:Saic Allowed Value range:NO(NO),YES(YES) Explanation:None. Default value:None |
Modify the power control basic parameters of the cell (Index Type = BYIDX(By Index); Cell Index = 0): MOD CELLPWRBASIC: IDXTYPE=BYIDX, CELLIDX=0, PCADJPERIOD=3, ULSSHIGHTHRED=35, ULSSLOWTHRED=25, ULQHIGHTHRED=0, ULQLOWTHRED=2, DLSSHIGHTHRED=35, DLSSLOWTHRED=25, DLQHIGHTHRED=0, DLQLOWTHRED=2, PWRCTRLSW=HW2, AMRSADLUPGRADE=0;