A configuration command that modifies the parameters of the DATU/GATM. In this command, the following parameters uniquely identify a board:
BTS Index or BTS Name
Subrack No.
Slot No.
1. BTS3012, BTS3012AE, and BTS3012_II support configuring the DATU.
2. DBS3900 GSM, BTS3900 GSM, BTS3900A GSM, DBS3036, BTS3036, and BTS3036A support configuring the GATM.
3. BTS3006C and BTS3002E support configuring the DATM.
4. When Board Parameter Configuration Enabled is set to NO(NO), other board parameters are reset with the default values.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning:Index Type Value range:BYNAME(By Name),BYIDX(By Index) Explanation:Index type. Default value:None |
BTSIDX | BTS Index | Meaning:BTS Index Value range:0~2047 Explanation:This parameter specifies the index number of a BTS. Each BTS is numbered uniquely in a BSC. Default value:None |
BTSNAME | BTS Name | Meaning:BTS Name Value range:1-32 characters Explanation:This parameter specifies the name of a BTS. The name of each BTS is unique in a BSC. Excluding the invalid characters ';',',','"','''','=','\','%%','+++','&','#'. Default value:None |
SRN | Subrack No. | Meaning:Subrack No. Value range:0~53 Explanation:None. Default value:None |
SN | Slot No. | Meaning:Slot No. Value range:0~23 Explanation:None. Default value:None |
CFGFLAG | Board Parameter Configuration Enabled | Meaning:Board Parameter Configuration Enabled Value range:NO(NO),YES(YES) Explanation:None. Default value:None |
AMPC0 | Feed Tri. 0 TMA Configuration | Meaning:Feed Tri. 0 TMA Configuration Value range:DISABLED(Disabled),ENABLED(Enabled) Explanation:This parameter specifies whether the DATU or GATM supplies power to the TMA on feed tributary 0. Default value:None |
MODE0 | Feed Tri. 0 Alarm Mode | Meaning:Feed Tri. 0 Alarm Mode Value range:MODE1(Mode1),MODE2(Mode2),MODE3(Mode3) Explanation:This parameter specifies the mode used by the DATU or GATM to report an alarm about feed tributary 0. The three modes are as follows: Mode 1: In this mode, there is only one alarm severity. The current for alarming is constant and higher than the normal operating current. Mode 2: In this mode, there are two alarm severities: warning alarm and critical alarm. The current for alarming is constant and higher than the normal operating current. Mode 3: In this mode, there are two alarm severalties: warning alarm and critical alarm. The current for reporting a warning alarm is a periodic pulse. The current for reporting a critical alarm is a constant current. Default value:None |
MAJORALMUP0 | Feed Tri. 0 TMA Over Critical Alm Thred. | Meaning:Feed Tri. 0 TMA Over Critical Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Critical Alarm when the feed current of the TMA on feed tributary 0 is too high. Default value:None |
MINORALMUP0 | Feed Tri. 0 TMA Over Warning Alm Thred. | Meaning:Feed Tri. 0 TMA Over Warning Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Warning Alarm when the feed current of the TMA on feed tributary 0 is too high. Default value:None |
ALMD0 | Feed Tri. 0 TMA Low Current Alm Thred. | Meaning:Feed Tri. 0 TMA Low Current Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Too Small Alarm when the feed current of the TMA on feed tributary 0 is too low. Default value:None |
AMPC1 | Feed Tri. 1 TMA Configuration | Meaning:Feed Tri. 1 TMA Configuration Value range:DISABLED(Disabled),ENABLED(Enabled) Explanation:This parameter specifies whether the DATU or GATM supplies power to the TMA on feed tributary 1. Default value:None |
MODE1 | Feed Tri. 1 Alarm Mode | Meaning:Feed Tri. 1 Alarm Mode Value range:MODE1(Mode1),MODE2(Mode2),MODE3(Mode3) Explanation:This parameter specifies the mode used by the DATU or GATM to report an alarm about feed tributary 1. The three modes are as follows: Mode 1: In this mode, there is only one alarm severity. The current for alarming is constant and higher than the normal operating current. Mode 2: In this mode, there are two alarm severities: warning alarm and critical alarm. The current for alarming is constant and higher than the normal operating current. Mode 3: In this mode, there are two alarm severalties: warning alarm and critical alarm. The current for reporting a warning alarm is a periodic pulse. The current for reporting a critical alarm is a constant current. Default value:None |
MAJORALMUP1 | Feed Tri. 1 TMA Over Critical Alm Thred. | Meaning:Feed Tri. 1 TMA Over Critical Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Critical Alarm when the feed current of the TMA on feed tributary 1 is too high. Default value:None |
MINORALMUP1 | Feed Tri. 1 TMA Over Warning Alm Thred. | Meaning:Feed Tri. 1 TMA Over Warning Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Warning Alarm when the feed current of the TMA on feed tributary 1 is too high. Default value:None |
ALMD1 | Feed Tri. 1 TMA Low Current Alm Thred. | Meaning:Feed Tri. 1 TMA Low Current Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Too Small Alarm when the feed current of the TMA on feed tributary 1 is too low. Default value:None |
AMPC2 | Feed Tri. 2 TMA Configuration | Meaning:Feed Tri. 2 TMA Configuration Value range:DISABLED(Disabled),ENABLED(Enabled) Explanation:This parameter specifies whether the DATU or GATM supplies power to the TMA on feed tributary 2. Default value:None |
MODE2 | Feed Tri. 2 Alarm Mode | Meaning:Feed Tri. 2 Alarm Mode Value range:MODE1(Mode1),MODE2(Mode2),MODE3(Mode3) Explanation:This parameter specifies the mode used by the DATU or GATM to report an alarm about feed tributary 2. The three modes are as follows: Mode 1: In this mode, there is only one alarm severity. The current for alarming is constant and higher than the normal operating current. Mode 2: In this mode, there are two alarm severities: warning alarm and critical alarm. The current for alarming is constant and higher than the normal operating current. Mode 3: In this mode, there are two alarm severalties: warning alarm and critical alarm. The current for reporting a warning alarm is a periodic pulse. The current for reporting a critical alarm is a constant current. Default value:None |
MAJORALMUP2 | Feed Tri. 2 TMA Over Critical Alm Thred. | Meaning:Feed Tri. 2 TMA Over Critical Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Critical Alarm when the feed current of the TMA on feed tributary 2 is too high. Default value:None |
MINORALMUP2 | Feed Tri. 2 TMA Over Warning Alm Thred. | Meaning:Feed Tri. 2 TMA Over Warning Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Warning Alarm when the feed current of the TMA on feed tributary 2 is too high. Default value:None |
ALMD2 | Feed Tri. 2 TMA Low Current Alm Thred. | Meaning:Feed Tri. 2 TMA Low Current Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Too Small Alarm when the feed current of the TMA on feed tributary 2 is too low. Default value:None |
AMPC3 | Feed Tri. 3 TMA Configuration | Meaning:Feed Tri. 3 TMA Configuration Value range:DISABLED(Disabled),ENABLED(Enabled) Explanation:This parameter specifies whether the DATU or GATM supplies power to the TMA on feed tributary 3. Default value:None |
MODE3 | Feed Tri. 3 Alarm Mode | Meaning:Feed Tri. 3 Alarm Mode Value range:MODE1(Mode1),MODE2(Mode2),MODE3(Mode3) Explanation:This parameter specifies the mode used by the DATU or GATM to report an alarm about feed tributary 3. The three modes are as follows: Mode 1: In this mode, there is only one alarm severity. The current for alarming is constant and higher than the normal operating current. Mode 2: In this mode, there are two alarm severities: warning alarm and critical alarm. The current for alarming is constant and higher than the normal operating current. Mode 3: In this mode, there are two alarm severalties: warning alarm and critical alarm. The current for reporting a warning alarm is a periodic pulse. The current for reporting a critical alarm is a constant current. Default value:None |
MAJORALMUP3 | Feed Tri. 3 TMA Over Critical Alm Thred. | Meaning:Feed Tri. 3 TMA Over Critical Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Critical Alarm when the feed current of the TMA on feed tributary 3 is too high. Default value:None |
MINORALMUP3 | Feed Tri. 3 TMA Over Warning Alm Thred. | Meaning:Feed Tri. 3 TMA Over Warning Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Warning Alarm when the feed current of the TMA on feed tributary 3 is too high. Default value:None |
ALMD3 | Feed Tri. 3 TMA Low Current Alm Thred. | Meaning:Feed Tri. 3 TMA Low Current Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Too Small Alarm when the feed current of the TMA on feed tributary 3 is too low. Default value:None |
AMPC4 | Feed Tri. 4 TMA Configuration | Meaning:Feed Tri. 4 TMA Configuration Value range:DISABLED(Disabled),ENABLED(Enabled) Explanation:This parameter specifies whether the DATU or GATM supplies power to the TMA on feed tributary 4. Default value:None |
MODE4 | Feed Tri. 4 Alarm Mode | Meaning:Feed Tri. 4 Alarm Mode Value range:MODE1(Mode1),MODE2(Mode2),MODE3(Mode3) Explanation:This parameter specifies the mode used by the DATU or GATM to report an alarm about feed tributary 4. The three modes are as follows: Mode 1: In this mode, there is only one alarm severity. The current for alarming is constant and higher than the normal operating current. Mode 2: In this mode, there are two alarm severities: warning alarm and critical alarm. The current for alarming is constant and higher than the normal operating current. Mode 3: In this mode, there are two alarm severalties: warning alarm and critical alarm. The current for reporting a warning alarm is a periodic pulse. The current for reporting a critical alarm is a constant current. Default value:None |
MAJORALMUP4 | Feed Tri. 4 TMA Over Critical Alm Thred. | Meaning:Feed Tri. 4 TMA Over Critical Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Critical Alarm when the feed current of the TMA on feed tributary 4 is too high. Default value:None |
MINORALMUP4 | Feed Tri. 4 TMA Over Warning Alm Thred. | Meaning:Feed Tri. 4 TMA Over Warning Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Warning Alarm when the feed current of the TMA on feed tributary 4 is too high. Default value:None |
ALMD4 | Feed Tri. 4 TMA Low Current Alm Thred. | Meaning:Feed Tri. 4 TMA Low Current Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Too Small Alarm when the feed current of the TMA on feed tributary 4 is too low. Default value:None |
AMPC5 | Feed Tri. 5 TMA Configuration | Meaning:Feed Tri. 5 TMA Configuration Value range:DISABLED(Disabled),ENABLED(Enabled) Explanation:This parameter specifies whether the DATU or GATM supplies power to the TMA on feed tributary 5. Default value:None |
MODE5 | Feed Tri. 5 Alarm Mode | Meaning:Feed Tri. 5 Alarm Mode Value range:MODE1(Mode1),MODE2(Mode2),MODE3(Mode3) Explanation:This parameter specifies the mode used by the DATU or GATM to report an alarm about feed tributary 5. The three modes are as follows: Mode 1: In this mode, there is only one alarm severity. The current for alarming is constant and higher than the normal operating current. Mode 2: In this mode, there are two alarm severities: warning alarm and critical alarm. The current for alarming is constant and higher than the normal operating current. Mode 3: In this mode, there are two alarm severalties: warning alarm and critical alarm. The current for reporting a warning alarm is a periodic pulse. The current for reporting a critical alarm is a constant current. Default value:None |
MAJORALMUP5 | Feed Tri. 5 TMA Over Critical Alm Thred. | Meaning:Feed Tri. 5 TMA Over Critical Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Critical Alarm when the feed current of the TMA on feed tributary 5 is too high. Default value:None |
MINORALMUP5 | Feed Tri. 5 TMA Over Warning Alm Thred. | Meaning:Feed Tri. 5 TMA Over Warning Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Warning Alarm when the feed current of the TMA on feed tributary 5 is too high. Default value:None |
ALMD5 | Feed Tri. 5 TMA Low Current Alm Thred. | Meaning:Feed Tri. 5 TMA Low Current Alm Thred. Value range:0~2000 Explanation:This parameter specifies the threshold for reporting a TMA Feed Current Too Small Alarm when the feed current of the TMA on feed tributary 5 is too low. Default value:None |
1. Modify the parameters of the DATU (Index Type = BYIDX(By Index); BTS Index = 4; Subrack No. = 0; Slot No. = 3; Board Parameter Configuration Enabled = NO(NO)): MOD DATUBP: IDXTYPE=BYIDX, BTSIDX=4, SRN=0, SN=3, CFGFLAG=NO; 2. Modify the parameters of the DATU (Index Type = BYIDX(By Index); BTS Index = 4; Subrack No. = 0; Slot No. = 3; Board Parameter Configuration Enabled = YES(YES); Feed Tri 0 TMA Configuration = ENABLED(Enabled); Feed Tri. 0 TMA Over Critical Alm Thred. = 1000; Feed Tri. 0 TMA Low Current Alm Thred. = 500): MOD DATUBP: IDXTYPE=BYIDX, BTSIDX=4, SRN=0, SN=3, CFGFLAG=YES, AMPC0=ENABLED, MAJORALMUP0=1000, ALMD0=500;