Add BTS Board(ADD BTSBRD)

Function

A configuration command that adds a BTS board.

Note

To add a CDU or EDU, run the ADD ANTFEEDER command; to add a TRX board, run the ADD TRX or ADD RXUBRD command. The ADD RXUBRD command applies to only the TRX boards of the DBS3900 GSM, BTS3900 GSM, BTS3900A GSM, DBS3036, BTS3036, BTS3036A, and BTS3900E GSM.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning:Index Type

Value range:BYNAME(By Name),BYIDX(By Index)

Explanation:Index type.

Default value:None

BTSIDX BTS Index

Meaning:BTS Index

Value range:0~2047

Explanation:This parameter specifies the index number of a BTS. Each BTS is numbered uniquely in a BSC.

Default value:None

BTSNAME BTS Name

Meaning:BTS Name

Value range:1-32 characters

Explanation:This parameter specifies the name of a BTS. The name of each BTS is unique in a BSC. Excluding the invalid characters ';',',','"','''','=','\','%%','+++','&','#'.

Default value:None

SRN Subrack No.

Meaning:Subrack No.

Value range:0~53

Explanation: This parameter specifies the unique number of the subrack where the board is located within each BTS in a BSC.

Default value:None

SN Slot No.

Meaning:Slot No.

Value range:0~23

Explanation: This parameter specifies the number of the slot in which a BTS board is located.

Default value:None

CNT Cabinet Type

Meaning:Cabinet Type

Value range:BTS22C,BTS20,BTS30,BTS312,BTS3001C,BTS3001CP,BTS3002C,BTS3012A,BTS3006A,BTS3012,BTS3006C,BTS3002E,BTS3012AE,BTS3012_II,DBS3900_GSM,BTS3900_GSM,BTS3900A_GSM,DBS3036,BTS3036,BTS3036A,BTS3900E_GSM

Explanation:This parameter specifies which type the cabinet pertains to. Different cabinet types show different slot layout in the subracks.

Default value:None

BT Board Type

Meaning:Board Type

Value range:OMU(OMU),BIE(BIE),PWC(PWC),EAC_EMUA(EAC_EMUA),MCK(MCK),DTMU(DTMU),DATM_DATU(DATM_DATU),NFCB(NFCB),EMU_DEMU(EMU_DEMU),DPMU(DPMU),DCBM_DCOM(DCBM_DCOM),DHEU(DHEU),ECOM(ECOM),MFU(MFU),MPW(MPW),MCD(MCD),IASU(IASU),PTU(PTU),TMU(TMU),PSU_APSU(PSU_APSU),PMU_APMU(PMU_APMU),3001C_MFU(3001C_MFU),TEU(TEU),TES(TES),PBU(PBU),SCU(SCU),MDU(MDU),UPEU(UPEU),UEIU(UEIU),FMU(FMU),FMUA(FMUA),DTCU(DTCU),GATM(GATM),DGPS(DGPS),USCU(USCU)

Explanation:This parameter is used to differentiate boards with unique identifiers in the BTS. Some boards are of the same type but with different names in the system. These boards are represented by the names like EMU_DEMU.

Default value:None

ASSOCIATEDRRU Associated RRU Board No.

Meaning:Associated RRU Board No.

Value range:0~35

Explanation:This parameter specifies the number of the RRU that is connected to this board.

Default value:None

Example

Add a DTMU (BTS Index = 5; Subrack No. = 0; Slot No. = 1; Cabinet Type = BTS3012AE; Board Type = DTMU(DTMU)):
ADD BTSBRD: IDXTYPE=BYIDX, BTSIDX=5, SRN=0, SN=1, CNT=BTS3012AE, BT=DTMU;
Related reference
Add BTS(ADD BTS)

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.