1. Resetting a Pb-interface circuit may affect the services on the interface.
2. If the PCU is built in the BSC, this command is not supported.
ID | Name | Description |
---|---|---|
SRN | Subrack No. | Meaning: subrack number Value range: 0-11 Explanation: 1. This parameter specifies the number of a subrack. 2. A key field that identifies the state reset for a Pb-interface CIC and indicates the subrack number of the Pb-interface CIC to be reset. Default value: None |
PCU | PCU No. | Meaning: PCU number corresponding to the CIC Value range: 0-31 Explanation: A key field that identifies the state reset for a Pb-interface CIC and indicates the PCU number of the Pb-interface CIC to be reset. Default value: None (indicating slot 0 and slot 15) |
OPMODE | Operation Mode | Meaning: operation mode Value range: BYCICRANGE(BY CIC RANGE), BYCICVALUE(BY CIC VALUE) Explanation: 1. 0: searching by CIC range; 1: searching by CIC value 2. A key field that identifies the state reset for a Pb-interface CIC and indicates the searching mode for the Pb-interface CIC to be reset. Default value: None |
STARTCIC | Start CIC | Meaning: start CIC Value range: 0-65535 Explanation: 1. The start CIC of the Pb-interface CIC range to be reset. 2. This parameter is mandatory if the searching is based on CIC range. Default value: None |
ENDCIC | End CIC | Meaning: end CIC Value range: 0-65535 Explanation: 1. The end CIC of the Pb-interface CIC range to be reset. 2. This parameter is mandatory if the searching is based on CIC range. Default value: None |
CIC | CIC | Meaning: CIC number of the board Value range: 0-65535 Explanation: 1. The number of the Pb-interface CIC to be reset. 2. This parameter is mandatory if the searching is based on a specified CIC number. 3. This parameter supports multiple values. Default value: None |
1. Reset a Pb-interface circuit (Subrack No. = 0; PCU No. = 2; Operation Mode = BYCICVALUE(BY CIC VALUE); CIC = 4): RST PBCIC: SRN=0, PCU=2, OPMODE=BYCICVALUE, CIC=4; 1. Reset the Pb-interface circuits (Subrack No. = 0; PCU No. = 2; Operation Mode = BYCICVALUE(BY CIC VALUE); CIC = 2&3): RST PBCIC: SRN=0, PCU=2, OPMODE=BYCICVALUE, CIC=2&3; Note: If the subrack or PCU is not configured, or the specified CIC is not in the PCU, the MML client prompts a parameter error.