Unblock Pb Interface CIC(UBL PBCIC)

Function

An OM command that unblocks a specified Pb-interface circuit.

Note

1. Blocking or unblocking a Pb-interface circuit may change the circuit status and affect the services on the Pb-interface.

2. If the PCU is built in the BSC, this command is not supported.

Parameters

ID Name Description
SRN Subrack No.

Meaning: subrack number

Value range: 0-11

Explanation:

1. This parameter specifies the number of a subrack.

2. A key field that identifies the unblocking for a Pb-interface CIC and indicates the subrack number of the Pb-interface CIC to be unblocked.

Default value: None

PCU PCU No.

Meaning: PCU number corresponding to the CIC

Value range: 0-31

Explanation: A key field that identifies the unblocking for a Pb-interface CIC and indicates the PCU number corresponding to the Pb-interface CIC to be unblocked.

Default value: None

OPMODE Operation Mode

Meaning: operation mode

Value range: BYCICRANGE(BY CIC RANGE), BYCICVALUE(BY CIC VALUE)

Explanation:

1. operating by CIC range or operating by CIC value

2. A key field that identifies the unblocking for a Pb-interface CIC and indicates the searching mode for the Pb-interface CIC to be unblocked.

Default value: None

STARTCIC Start CIC

Meaning: start CIC

Value range: 0-65535

Explanation:

1. The start CIC of the Pb-interface CIC range to be unblocked.

2. This parameter is mandatory if the searching is based on CIC range.

Default value: None

ENDCIC End CIC

Meaning: end CIC

Value range: 0-65535

Explanation:

1. The end CIC of the Pb-interface CIC range to be unblocked.

2. This parameter is mandatory if the searching is based on CIC range.

Default value: None

CIC CIC

Meaning: CIC number of the board

Value range: 0-65535

Explanation:

1. The number of the Pb-interface CIC to be unblocked.

2. This parameter is mandatory if the searching is based on a specified CIC number.

3. This parameter supports multiple values.

Default value: None

Example

1. Unblock a Pb-interface circuit (Subrack No. = 0; PCU No. = 4; Operation Mode = BYCICVALUE(BY CIC VALUE); CIC = 4):
UBL PBCIC: SRN=0, PCU=4, OPMODE=BYCICVALUE, CIC=4;
2. Unblock a Pb-interface circuit (Subrack No. = 0; PCU No. = 4; Operation Mode = BYCICVALUE(BY CIC VALUE); CIC = 4&6):
UBL PBCIC: SRN=0, PCU=4, OPMODE=BYCICVALUE, CIC=4&6;
3. Unblock a Pb-interface circuit (Subrack No. = 0; PCU No. = 4; Operation Mode = BYCICRANGE(BY CIC RANGE); Start CIC = 2; End CIC = 15):
UBL PBCIC: SRN=0, PCU=4, OPMODE=BYCICRANGE, STARTCIC=2, ENDCIC=15;
Note:
If the specified CIC is not in the PCU, the MML client prompts a parameter error.
Related reference
Block Pb Interface CIC(BLK PBCIC)
Display Pb Interface CIC Status(DSP PBCIC)
Reset Pb Interface CIC(RST PBCIC)

Huawei Proprietary and Confidential