An OM command that starts the FR port loopback. After the FR port loopback starts, the BSC periodically sends loopback packets.
ID | Name | Description |
---|---|---|
SRN | Subrack No. | Meaning: subrack number Value range: 0-11 Explanation: 1. This parameter specifies the subrack where the loopback is initiated. 2. The subrack number uniquely identifies a subrack. Default value: None |
SN | Slot No. | Meaning: slot number Value range: 0-27 Explanation: 1. This parameter specifies the slot number where the loopback is initiated. 2. The subrack number and slot number uniquely identify a board. Default value: None |
PN | Port No. | Meaning: port number Value range: 0-31 Explanation: This parameter specifies the port where the FR loopback is initiated. Default value: None |
BCID | BC Id | Meaning: BC ID Value range: 0-255 Explanation: This parameter specifies the BC where the FR loopback is initiated. Default value: None |
LOOPMODE | Loop Type | Meaning: loopback mode Value range: BYLOCAL(By Local Loop), BYREMOTE(By Remote Loop) Explanation: This parameter specifies the loopback mode. BYLOCAL indicates local loopback and BYREMOTE indicates remote loopback. Default value: None |
TMLEN | Time Length[m] | Meaning: loopback duration Value range: 1-120 Explanation: This parameter specifies the loopback duration (unit: minute). Default value: None |
PKTLEN | Packet Length[byte] | Meaning: Size of the loopback data packet Value range: 2-1500 Explanation: 1. This parameter specifies the size of the loopback data packet. 2. The unit of this parameter is byte. Default value: None |