ZTA03445:BSCRPT_GCC_INTRABSC_OUTCELL_HO_CMD
In the internal inter-cell VGCS TCH handover, after the newly assigned TCH is activated successfully, the target cell sends a message to notify of the originating cell that the TCH is ready for handover. After receiving the message, the originating cell sends a HANDOVER COMMAND message to the MS. This measurement provides the number of HANDOVER COMMAND messages sent by the originating cell (serving cell).
Integer number or integer.
At the end of each granularity period, this counter is measured by using the following formula. For details, see Outgoing Internal Inter-Cell VGCS TCH Handovers.
Outgoing Internal Inter-Cell VGCS TCH Handovers per BSC = Outgoing Internal Inter-Cell VGCS TCH Handovers
(That is, the total of the counter Outgoing Internal Inter-Cell VGCS TCH Handover in each cell of the BSC.)