ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Subrack No. |
2 | Slot No. | Slot No. |
3 | Cpu No. | CPU No. |
4 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Y=> Clear the parent alarm according to the corresponding handling suggestions. Check whether the alarm is cleared.
N=> Go to 2.
Correlated parent alarm
20007 Faulty Clock Source 0 from the Rear Interface Board to the Backplane of the GSCU
The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.
The reference clock of the subrack is configured with the line clock, which is only the LINE0 clock, not the LINE1 clock.
20008 Faulty Clock Source 1 from the Rear Interface Board to the Backplane of the GSCU
The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.
The reference clock of the subrack is configured with the line clock, which is only the LINE1 clock, not the LINE0 clock.
When 20007 Faulty Clock Source 0 from the Rear Interface Board to the Backplane of the GSCU, 20008 Faulty Clock Source 1 from the Rear Interface Board to the Backplane of the GSCU, and this alarm have the same Subrack No. and Slot No. in the alarm location information, and when the reference clock of the subrack is configured with both LINE0 and LINE1, this alarm occurs in the case that two parent alarms occur at the same time.
20009 Faulty 8 kHz Clock Source from the Active GGCU to the Backplane of the GSCU
The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.
The reference clock of the subrack is configured with the backplane clock.
20013 Faulty GGCU 8 kHz Clock Source for the Front Panel of the GSCU
The parent alarm and the child alarm have the same Subrack No. and Slot No. in the alarm location information.
The reference clock of the subrack is configured with the panel clock.
Y => Alarm occurs to other clock sources. Remove the alarm by referring to other clock sources.
N => No alarm occurs. Please contact Huawei Customer Service Center.