ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 147:PBU |
3 | Board No. | Number of the fault board 0:PBU 0 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 3: BTS30 5: BTS312 10: BTS3012A 11: BTS3006A |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Y=> Go to Step b.
N=> Install the PBU. The alarm handling ends.
Y=> No manual handling is required since the alarm is an normal response. The alarm handing ends.
N=> Go to Step 2.
Check whether there are such correlated alarms as ALM-2166 TRX Clock Prompt Alarm on the Alarm management system.
Y=> If any. Replace the TDU. View whether the Alarm is cleared.The alarm is cleared, Alarm handling is completed. The alarm is not cleared, Go to Step 3.
N=> If no. Go to Step 3.
Replace the PBU and check whether the alarm is cleared.
Y=> The alarm handling ends.
N=> Go to Step 4.
Replace the TMU and check whether the alarm is cleared.
Y=> The alarm handling ends.