ALM-8626 TRX/CDU power off alarm

Description

This alarm is triggered when all of the TRXs and the CDUs of the BTS are powered down because the AC power supply for the BTS3012A shuts off and the output voltage from the battery is under the normal range or internal temperature of the cabinet is higher than the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
8626 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

140:OSSU

3 Board No.

Number of the fault board

0:OSSU0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0、1: The battery is exhausted and the TMU disconnects the power supply of the TRX and CDU. 2:There is no AC power supply. 3:The battery fails.

1: The power-off is caused by the over temperature of the cabinet.

2: The power-off is caused by the heat exchanger alarm.

3: The power-off is caused by the air conditioner alarm.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When this alarm occurs, the BTS cannot communicate with the other devices.

System Actions

All of the TRXs and the CDUs are powered down.

Possible Causes

  • The TMU shuts down the power for the TRXs and the CDUs since the power stored in the battery is almost used up.
  • There is no mains input.
  • The internal temperature of the cabinet is higher than the threshold.

Procedure

  1. Check the battery

    Judge whether the battery is in normal operation according to the data given in the table below, which shows the correspondence relation among the current, power and the life-span after a recharge.

    Configuration Power (W) Three hours (life-span) Four hours (life-span) Six hours (life-span) Eight hours (life-span)

    S1/1/1 1.220 260Ah 300Ah 400Ah 500Ah

    S2/2/2 1.650 300Ah 400Ah 500Ah 650Ah

    S3/3/3 2.100 400Ah 500Ah 650Ah 800Ah

    S4/4/4 2.520 500Ah 650Ah 800Ah -

    Y=>The alarm handling ends. The alarm occurs because the system starts the hierarchical power supply mode for protection.

    N=>Please contact Huawei Customer Service Center.The alarm may be caused by error in BTS software configuration or fault of the battery.

  2. Check the internal temperature of the cabinet

    Check if the alarm subsystem reports the ALM-6412 Over Temperature Alarm at the same time. Handle according to the handling suggestions in ALM-6412 Over Temperature Alarm, and observe if the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Please contact Huawei Customer Service Center.

  3. Check whether the air conditioner or heat exchanger is faulty

    Check if the alarm subsystem reports the ALM-8564 BTS3012A Air-Conditioner Alarm or ALM-8580 Heat Exchanger Fault Alarm at the same time. Handle according to the handling suggestions in ALM-8564 BTS3012A Air-Conditioner Alarm or ALM-8580 Heat Exchanger Fault Alarm , and observe if the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Please contact Huawei Customer Service Center.