This describes the mapping between ports and TRXs in BTS combined cabinets and cabinet groups.
Table 1 lists the mapping between ports and TRXs of the BTS30 that is configured with only one TMU in cabinet 0. Table 2 lists the mapping between ports and TRXs of the BTS30 that is configured with two TMUs in cabinet 0.
Table 3 lists the mapping between ports and TRXs of the BTS312 that is configured with only one TMU in cabinet 0. Table 4 lists the mapping between ports and TRXs of the BTS312 that is configured with two TMUs in cabinet 0.
Cabinet Group No. |
Port No. |
TRX No. |
---|---|---|
0 |
0-1 |
0-5 |
1 |
- |
- |
2 |
- |
- |
The BTS3001C+ is the same as the BTS3001C in the mapping between ports and TRXs.
Cabinet Group No. |
Port No. |
TRX No. |
---|---|---|
0 |
0-1 |
0-5 |
1 |
- |
- |
2 |
- |
- |
The BTS3002C does not support the configuration of the extension cabinet.
Cabinet Group No. |
Port No. |
TRX No. |
---|---|---|
0 |
0-7 |
0-23 |
1 |
8-15 |
24-47 |
2 |
16-23 |
48-71 |
The preceding mapping applies to only the BTS3012 that is not in BM/TC separated mode. For the BTS3012 in BM/TC separated mode, the mapping between the logical TRX number and the port number is not fixed.
Cabinet Group No. |
Port No. |
TRX No. |
---|---|---|
0 |
0-3 (connected to the BSC), 4-7 (internal connection) |
0, 1, 6, 7, 12, 13 |
1 |
8-11 (connected to the BSC), 12-15 (internal connection) |
18, 19, 24, 25, 30, 31 |
2 |
16-19 (connected to the BSC), 20-23 (internal connection) |
36, 37, 42, 43, 48, 49 |
When the BTS3012 II is combined with the BTS30, BTS3012 II, or BTS312, only the BTS3012 II can be configured as the main cabinet group.
The current Huawei BTSs support the mixed configuration of the single-transceivers and double-transceivers as well as the mixed configuration of the double-transceivers of different types. The principles of mixed configuration are as follows: