BTS Combined Cabinets and Cabinet Groups

This describes the mapping between ports and TRXs in BTS combined cabinets and cabinet groups.

Combined Cabinets and Cabinet Groups of the Same BTS Type

Table 1 lists the mapping between ports and TRXs of the BTS30 that is configured with only one TMU in cabinet 0. Table 2 lists the mapping between ports and TRXs of the BTS30 that is configured with two TMUs in cabinet 0.

Table 1 Mapping between ports and TRXs of BTS30 (1)

Cabinet Group No.

Port No.

TRX No.

0

0-3

0-17

1

8-11

18-35

2

16-19

36-53

Table 2 Mapping between ports and TRXs of BTS30 (2)

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-17

1

8-11

18-35

2

16-19

36-53

Table 3 lists the mapping between ports and TRXs of the BTS312 that is configured with only one TMU in cabinet 0. Table 4 lists the mapping between ports and TRXs of the BTS312 that is configured with two TMUs in cabinet 0.

Table 3 Mapping between ports and TRXs of BTS312

Cabinet Group No.

Port No.

TRX No.

0

0-3

0-23

1

8-11

24-47

2

16-19

48-71

Table 4 Mapping between ports and TRXs of BTS312

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-23

1

8-11

24-47

2

16-19

48-71

Table 5 Mapping between ports and TRXs of the BTS3012A

Cabinet Group No.

Port No.

TRX No.

0

0-3

0-11

1

8-11

12-23

2

16-19

24-35

Table 6 Mapping between ports and TRXs of the BTS3001C

Cabinet Group No.

Port No.

TRX No.

0

0-1

0-5

1

-

-

2

-

-

NOTE:

The BTS3001C+ is the same as the BTS3001C in the mapping between ports and TRXs.

Table 7 Mapping between ports and TRXs of the BTS3002C

Cabinet Group No.

Port No.

TRX No.

0

0-1

0-5

1

-

-

2

-

-

NOTE:

The BTS3002C does not support the configuration of the extension cabinet.

Table 8 Mapping between ports and TRXs of the BTS3012

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-23

1

8-15

24-47

2

16-23

48-71

NOTE:

The preceding mapping applies to only the BTS3012 that is not in BM/TC separated mode. For the BTS3012 in BM/TC separated mode, the mapping between the logical TRX number and the port number is not fixed.

Table 9 Mapping between ports and TRXs of the BTS3012 II

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-17

1

8-15

24-41

2

16-23

48-65

Table 10 Mapping between ports and TRXs of the BTS3012AE

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-23

1

8-15

24-47

2

16-23

48-71

Table 11 Mapping between ports and TRXs of the BTS3006C

Cabinet Group No.

Port No.

TRX No.

0

0-3 (connected to the BSC), 4-7 (internal connection)

0-17

1

8-11 (connected to the BSC), 12-15 (internal connection)

18-35

2

16-19 (connected to the BSC), 20-23 (internal connection)

36-53

Table 12 Mapping between ports and TRXs of the BTS3006A

Cabinet Group No.

Port No.

TRX No.

0

0-3

0-5

1

8-11

6-11

2

16-19

12-17

Table 13 Mapping between ports and TRXs of the BTS3002E

Cabinet Group No.

Port No.

TRX No.

0

0-3 (connected to the BSC), 4-7 (internal connection)

0, 1, 6, 7, 12, 13

1

8-11 (connected to the BSC), 12-15 (internal connection)

18, 19, 24, 25, 30, 31

2

16-19 (connected to the BSC), 20-23 (internal connection)

36, 37, 42, 43, 48, 49

Combined Cabinets and Cabinet Groups of Different BTS Types

When the BTS3012 is combined with the BTS30, BTS3012, or BTS312, only the BTS3012 can be configured as the main cabinet group.
Table 14 Mapping between ports and TRXs of the combined BTS3012 and BTS30 cabinets

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-23

1

8-11

24-41

2

16-19

48-65

Table 15 Mapping between ports and TRXs of the combined BTS3012 and BTS30 cabinets

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-23

1

8-11

24-47

2

16-19

48-71

When the BTS3012 is combined with the BTS3012 II, either of them can be configured as the main cabinet group. Table 16 lists the mapping between ports and TRXs with the BTS3012 being the main cabinet group. Table 17 lists the mapping between ports and TRXs when the BTS3012 II serves as the main cabinet group.
Table 16 Mapping between ports and TRXs of combined cabinets formed by the BTS3012 and the BTS3012 II

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-23

1

8-11

24-41

2

16-19

48-65

Table 17 Mapping between ports and TRXs of combined cabinets formed by the BTS3012 II and the BTS3012

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-23

1

8-11

24-47

2

16-19

48-71

When the BTS3012 II is combined with the BTS30, BTS3012 II, or BTS312, only the BTS3012 II can be configured as the main cabinet group.

Table 18 Mapping between ports and TRXs of combined cabinets formed by the BTS3012 II and the BTS30

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-17

1

8-11

24-41

2

16-19

48-65

Table 19 Mapping between ports and TRXs of combined cabinets formed by the BTS3012 II and the BTS312

Cabinet Group No.

Port No.

TRX No.

0

0-7

0-17

1

8-11

24-47

2

16-19

48-71

Mixed Configuration of TRXs

The current Huawei BTSs support the mixed configuration of the single-transceivers and double-transceivers as well as the mixed configuration of the double-transceivers of different types. The principles of mixed configuration are as follows:

Related tasks
Configuring the Internal Connection of a BTS

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.