Configuring the Local NSVL

This describes how to configure the local NSVL (NSVL on the BSC side) in Gb over IP mode. The local NSVL is responsible for the data transmission between the BSC and the SGSN.

ScenarioBSC initial configuration and BSC capacity expansion
Mandatory/OptionalOptional. The local NSVL is configured only when the Gb interface uses the IP transmission mode.

Prerequisites

Preparation

Table 1 Example of data to be negotiated and planned for configuring the local NSVL on the Gb interface

Parameter

Example

Source

Local NSVL Identifier

0

Negotiation with the peer

NSE Identifier

1

Negotiation with the peer

IP Address

192.168.70.1

Negotiation with the peer

UDP Port No.

0

Negotiation with the peer

GFGUG Board Subrack No.

0

BSC internal planning

GFGUG Board Slot No.

18

BSC internal planning

Signaling Load Weight

100

Negotiation with the peer

Traffic Load Weight

100

Negotiation with the peer

Procedure

  1. On the BSC6000 Local Maintenance Terminal, right-click GFGUG.
  2. Choose Configure Local NSVL from the shortcut menu. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Configure Local NSVL dialog box

  3. Click Add. A dialog box is displayed, as shown in Figure 2.

    Figure 2 Add Local NSVL dialog box

  4. Set the parameters by referring to Table 1.
  5. Click OK to return to the dialog box, as shown in Figure 1.
  6. Click Finish. The configuration of the local NSVL on the Gb interface is complete.