Configuring the Remote NSVL

This describes how to configure the remote NSVL (NSVL on the SGSN side) in Gb over IP mode. The remote NSVL is responsible for the data transmission between the BSC and the SGSN.

ScenarioBSC initial configuration and BSC capacity expansion
Mandatory/OptionalOptional. The remote NSVL is configured only when the Gb interface uses the IP transmission mode.

Prerequisites

Preparation

Table 1 Example of data to be negotiated and planned for configuring the remote NSVL on the Gb interface

Parameter

Example

Source

Remote NSVL Identifier

1

Negotiation with the peer

NSE Identifier

1

Negotiation with the peer

IP Address

172.16.124.25

Negotiation with the peer

UDP Port No.

0

Negotiation with the peer

Signaling Load Weight

100

Negotiation with the peer

Traffic Load Weight

100

Negotiation with the peer

Procedure

  1. On the BSC6000 Local Maintenance Terminal, right-click the BSC6000 root node.
  2. Choose Configure PCU Data > Configure Remote NSVL from the shortcut menu. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Configure Remote NSVL dialog box

  3. Click Add. A dialog box is displayed, as shown in Figure 2.

    Figure 2 Add Remote NSVL dialog box

  4. Set the parameters by referring to Table 1.
  5. Click OK to return to the dialog box, as shown in Figure 1.
  6. Click Finish. The configuration of the remote NSVL on the Gb interface is complete.