This describes how to add a PCU to process the PS services.
Scenario | BSC initial configuration and BSC capacity expansion |
Mandatory/Optional | Optional. You need to configure the PCU only when the external PCU is used. |
NOTE: - A maximum of 32 PCUs can be configured for the BSC.
- The name and number of each PCU must be unique.
Prerequisite
Preparation
Table 1 Example of the data negotiated and planned for adding a PCU
Parameter
|
Example
|
Source
|
PCU No.
|
1
|
BSC internal planning
|
PCU Name
|
PCU 1
|
BSC internal planning
|
Operator Name
|
46000
|
Network planning
|
Procedure
- On the BSC6000 Local Maintenance Terminal, right-click the BSC6000 root node.
- Choose from the shortcut menu. A dialog box is displayed, as shown in Figure 1.
Figure 1 Configure PCU dialog box
- Click Add. A dialog box is displayed, as shown in Figure 2.
Figure 2 Adding a PCU
- Set the parameters by referring to Table 1.
- Click OK to return to the dialog box, as shown in Figure 1.
- Click Finish. The addition of the PCU is complete.
- Repeat 1 through 6 to add multiple PCUs.