Adding a PCU

This describes how to add a PCU to process the PS services.

ScenarioBSC initial configuration and BSC capacity expansion
Mandatory/OptionalOptional. You need to configure the PCU only when the external PCU is used.
NOTE:
  • A maximum of 32 PCUs can be configured for the BSC.
  • The name and number of each PCU must be unique.

Prerequisite

None.

Preparation

Table 1 Example of the data negotiated and planned for adding a PCU

Parameter

Example

Source

PCU No.

1

BSC internal planning

PCU Name

PCU 1

BSC internal planning

Operator Name

46000

Network planning

Procedure

  1. On the BSC6000 Local Maintenance Terminal, right-click the BSC6000 root node.

  2. Choose Configure PCU Data > Configure PCU from the shortcut menu. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Configure PCU dialog box

  3. Click Add. A dialog box is displayed, as shown in Figure 2.

    Figure 2 Adding a PCU

  4. Set the parameters by referring to Table 1.
  5. Click OK to return to the dialog box, as shown in Figure 1.
  6. Click Finish. The addition of the PCU is complete.
  7. Repeat 1 through 6 to add multiple PCUs.