ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 65:DTRU/GTRU/DDRM 88:DRRU 92:DRFU 96:MRRU 100:MRFU 101:GRFU 102:GRRU 151:QTRU |
3 | Board No. | Number of the fault board |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
The TRX cannot communicate with the BSC. Therefore, the faulty TRX cannot carry services normally and automatically shuts down the power amplifier. If the faulty TRX is the BCCH TRX, the services of the cell where the faulty TRX is located are disrupted.
When the LAPD alarm is generated, the TRX tries to reset the interface chip. If this alarm is generated on the BCCH TRX and if the TRX aiding function is enabled, the BCCH switchover is triggered in the case that this alarm is not cleared within two minutes.
Y => The alarm exists on all the TRXs in the TRX board. Go to step b.
N => The alarm does not exist on all the TRXs in the TRX board. Go to 2.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => 4714 E1/T1 Local Alarm or 4716 E1/T1 Remote Alarm is reported on the LMT. Go to step b.
N => Neither 4714 E1/T1 Local Alarm nor 4716 E1/T1 Remote Alarm is reported on the LMT. Go to 3.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
In the case of combined cabinets or cabinet groups, go to step a. In the case of cascaded BTSs, go to step k.
In other cases, go to [4].
Y => If the alarm is located in the extension cabinet or extension cabinet group, go to step b. If the alarm is located in the lower-level BTS, go to step j.
N => The alarm is only located in the main cabinet. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step i.
Y => A faulty TRX exists. Go to step j.
N => No faulty TRX. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Combined cabinets or cabinet groups are not applied to the BTS3036/BTS3900 series.
Y => The transmission link of the current-level BTS is normal. Go to 5.
N => The transmission link of the current-level BTS is abnormal. Go to step b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 5.
Y => The 64 kbit/s timeslot cross-connection or timeslot compressing devices are used. Go to 6.
N => The 64 kbit/s timeslot cross-connection or timeslot compressing devices are not used. Go to 8.
Y => Consistent. Go to 8.
N => Inconsistent. Go to 7.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 8.
Y => A faulty TRX exists. Go to step b.
N => All the TRXs are normal. Go to 9.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step c.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 9.
Check the settings of the DIP switch bits on the TMU. Ensure that the settings are correct. Check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 10.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 11.
Y => All the other BTSs have the same alarm. Go to step a.
N => Not all the other BTSs have the same alarm. Go to step b.
a Replace the BSC Abis interface board. Check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step b.