ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 65:DTRU/GTRU/DDRM 88:DRRU 92:DRFU 96:MRRU 100:MRFU 101:GRFU 102:GRRU 151:QTRU |
3 | Board No. | Number of the fault board |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0: Receiving phase-lock loop 2 alarm(For the BTS3012 series)/Faulty hardware(For the BTS3900 series) 1: Receiving phase-lock loop 1 alarm 2: Transmitting phase-lock loop 2 alarm 3: Transmitting phase-lock loop 1 alarm 255: Test phase-lock loop alarm |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Check whether the LMT reports 4154 TRX main clock alarm.
Y => The alarm is reported. Rectify the fault according to the handling suggestions of 4154 TRX main clock alarm. Check whether the alarm is cleared. If the alarm is cleared, the alarm handling is complete. If the alarm is not cleared, go to step b.
N => The alarm is not reported. Go to step b.
Check whether the LMT reports 4184 TRX Clock Critical Alarm.
Y => The alarm is reported. Rectify the fault according to the handling suggestions of 4184 TRX Clock Critical Alarm. Check whether the alarm is cleared. If the alarm is cleared, the alarm handling is complete. If the alarm persists, go to step c.
N => The alarm is not reported. Go to step c.
Perform a level-4 reset or power-off reset of the BTS on the LMT or SMT.
You are advised to perform a power-off reset of the BTS, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step d.
Power off the BTS. Reinstall each module. Ensure that each module is in good contact with the backplane. Power on the BTS, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. The hardware of the TRX or the main control module may be faulty. Contact Huawei Customer Service Center.
Replace the TRU.
Replace the DTRU, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Reset the DTRU, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step b.
Replace the DTRU, and check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.