Adding a Common BTS (HDLC/HUB Transmission Mode)

This describes how to add a common BTS in HDLC/HUB transmission mode for the BSC, and how to configure the site device attributes, cell basic attributes, and TRX attributes.

ScenarioBSC initial configuration and BSC capacity expansion
Mandatory/OptionalMandatory
NOTE:

BTSs in HDLC transmission mode do not support the Config AbisByPass function. BTSs in HUB transmission mode do not support the Config Ring or Config AbisByPass function. In addition, the multiplexing ratio of a BTS in HDLC/HUB mode should not exceed 4:1 During the initial configuration of a BTS in HDLC/HUB transmission mode, the multiplexing ratio is 4:1 by default.

Only the BTS3012, BTS3012AE, BTS3006C, BTS3002E, and BTS3012 II support the HDLC transmission mode.

Only the BTS3012, BTS3012AE, and BTS3012 II support the HUB transmission mode.

Prerequisites

Preparation

NOTE:

The following procedure takes how to add a BTS in HUB transmission mode to the GEHUB in the GEPS.

Table 1 Example of the data negotiated and planned for adding a BTS

Parameter

Example

Source

Site Attributes

Site Name

BTS 1

Network planning

Site Type

BTS3012

Network planning

Upper-Level Port No.

0 Port of GEHUB

Network planning

Service Mode

HDLC HubBTS

Network planning

In Port

0

Network planning

Active

Deselected

Network planning

Config Ring

No

Network planning

Backup OML

No

Network planning

Cell Attributes

Cell Name

Cell 1

Network planning

Frequency Band

GSM900

Network planning

MCC

460

Network planning

MNC

01

Network planning

LAC

8240

Network planning

CI

1

Network planning

BCC

1

Network planning

NCC

1

Network planning

Cell Extension Type

Common cell

Network planning

Cell Type

Common cell

Network planning

TRX Attributes

Assigned Cell

Cell 1

Network planning

Frequency configuration

988 (main BCCH frequency), 994

Network planning

TRX configuration

TRX 0, TRX 1

Network planning

FH Mode

None

Network planning

Antenna feeder attributes

Tributary No.

Downlink Tributary

Network planning

Frequency Band

PGSM900

Network planning

TRX Transmit and Receive Relationship

TRX No.1: 0, A

TRX No.2: 1, B

Network planning

Procedure

  1. Start the wizard for adding a BTS.

    • When adding a BTS for the first time, you can start the wizard for adding a BTS only on the GEHUB in the GMPS or GEPS. On the BSC6000 Local Maintenance Terminal, right-click GEIUB in the GEPS.
    • If a BTS already exists, you can add a cascaded BTS under this BTS. On the Management Tree tab page, right-click a BTS.

  2. Choose Add Site from the shortcut menu. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Add Site dialog box (1)

  3. Click Add Site. A dialog box is displayed, as shown in Figure 2.

    Figure 2 Add New Site dialog box

  4. Set the parameters by referring to Table 1.

    NOTE:

    The Support Separate option is available only to the BTS3012, BTS3012 II, and BTS3012AE. When Support Separate is selected, the BTS3012, BTS3012 II, and BTS3012AE can be optionally configured with DTRUs or QTRUs.

    If Service Mode of a BTS is set to HDLC and Backup OML is set to Yes, then you need to select Configure Chain in Figure 7 after you add a cell.

  5. Click OK. A dialog box is displayed, as shown in Figure 3.

    Figure 3 Add Site dialog box (2)

  6. Click Next. A dialog box is displayed, as shown in Figure 4.

    Figure 4 Add Site dialog box (3)

  7. Select a BTS, and then click Add Cell. A dialog box is displayed, as shown in Figure 5.

    Figure 5 Adding a cell

  8. Set the parameters by referring to Table 1.

    NOTE:

    To add multiple cells at a time, set Number of Cells. The added cells are named in the format of current Cell Name + sequence number.

  9. Click OK. A dialog box is displayed, as shown in Figure 6.

    Figure 6 Add Site dialog box (4)

  10. Click Next. A dialog box is displayed, as shown in Figure 7.

    Figure 7 Add Site dialog box (5)

  11. Click Site Attributes. A dialog box is displayed, as shown in Figure 8.

    Figure 8 Site Device Attributes dialog box

  12. Double-click DDPU. A dialog box is displayed, as shown in Figure 9.

    Figure 9 Set Antenna Feeder Property dialog box

    NOTE:
    • This takes the configuration of one antenna feeder port on the DDPU as an example. If the antenna feeder port is not required, you can delete the DDPU.
    • You need to specify at least one TRX for the downlink tributary of the DDPU. For other tributaries, you can use the default settings.
    • The DDPU has two paths: A and B. The two paths are independent of each other. The data configurations of the DDPU must be consistent with the physical connections, and the frequency band of the TRX must be the same as that of the DDPU.

  13. Set the parameters by referring to Table 1, as shown in Figure 10.

    Figure 10 Setting antenna feeder attributes

  14. Right-click an idle slot holding the DTRU subrack in Figure 8 and then choose Add Board > TRU from the shortcut menu. A TRU is added.
  15. Right-click the added TRU and choose Binding logical TRX from the shortcut menu. A dialog box is displayed, as shown in Figure 11.

    Figure 11 Binding logical TRX dialog box

  16. Set Assigned Cell by referring to Table 1.
  17. Click OK to return to the dialog box, as shown in Figure 8.
  18. Repeat 14 through 17 to configure more TRUs.
  19. Click OK to return to the dialog box, as shown in Figure 7.
  20. Click Next. A dialog box is displayed, as shown in Figure 12.

    Figure 12 Add Site dialog box (6)

  21. Click Cell Attributes. A dialog box is displayed, as shown in Figure 13.

    Figure 13 Set Cell Attributes dialog box

  22. Set the basic attributes of the cell by referring to Table 1.

    NOTE:
    • For two cells, the values of at least one of the following parameters should be different: MCC, MNC, LAC, and CI.
    • If you select GPRS Support, the BSC must be configured with the built-in PCU. If the BTS does not support the GPRS function or the GPRS services are unavailable in the cell, do not select GPRS Support.

  23. Click OK to return to the dialog box, as shown in Figure 12.
  24. Click Finish. The configuration of the BTS is complete.
  25. Activating a BTS.
    1. On the Management Tree tab page of the BSC6000 Local Maintenance Terminal, right-click the target BTS and choose Site Operation > Set Site Active State from the shortcut menu. A dialog box is displayed, as shown in Figure 14.

      Figure 14 Set Site Active State dialog box

    2. Under Site Active State, select Activated. Then, click Finish to complete the BTS activation.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.