ALM-9696 PBU Communication Alarm

Description

This alarm is triggered when the communication between the TMU and the PBU fails.

Attribute

Alarm ID Alarm Severity Alarm Type
9696 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

147:PBU

3 Board No.

Number of the fault board

0:PBU 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When this alarm occurs, the corresponding PBU cannot work normally.

System Actions

None.

Possible Causes

  • The PBU is not in position, or is manually reset or powered down.
  • he TDU is damaged.
  • The PBU is damaged.
  • The TMU is damaged.

Procedure

  1. Check the PBU
    1. Check whether the PBU has been installed

      Y=> Go to Step b.

      N=> Install the PBU. The alarm handling ends.

    2. Check whether the PBU has been manually reset or powered down.

      Y=> No manual handling is required since the alarm is an normal response. The alarm handing ends.

      N=> Go to Step 2.

  2. Check whether the TDU is faulty

    Check whether there are such correlated alarms as ALM-4154 TRX main clock alarm, ALM-4124 TRX Hardware Prompt Alarm, ALM-4106 TRX Software Running Abnormal Alarm, ALM-4192 TRX communication alarm, ALM-9682 PBU Main Clock Alarm and ALM-9684 PBU Slave Clock Alarmon the alarm management system. Replace the TDU if any. View whether the original alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 3.

  3. Replace the PBU

    Replace the PBU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 4.

  4. Replace the TMU

    Replace the TMU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.