This describes the GSM initial configuration of the BTS3900 GSM/UMTS or BTS3900A GSM/UMTS for the BSC, which includes configurations of BTS attributes, logical TRXs, and cell attributes.
If... |
Then... |
---|---|
A site is added for the first time, |
Right-click the GFGUB/GOGUB interface board of the GMPS or GEPS, and then choose Figure 1. from the shortcut menu. A dialog box is displayed, as shown in |
A cascaded BTS is to be added under an existing BTS, |
Right-click the existing BTS on the management tree, and then choose Figure 1. from the shortcut menu. A dialog box is displayed, as shown in |
In the process of adding a BTS3900/BTS3900A, if Cfg RFU by Slot in the Add New Site dialog box is not configured, the procedures for configuring a BTS3900/BTS3900A and DBS3900 are the same. For details, see the configuration of the DBS3900.
With different settings of Cabinet Mapping Rule, both the location of the DRFU/GRFU/MRFU and the value of Hop set for the RXU chain are different. For details, see Mapping Rule of the RFU Cabinet.
According to the cabinet mapping rule, Mapping Rule for Two Cabinets should be configured for the two-level cascading of the RXU chain.
According to the cabinet mapping rule, Mapping Rule for Three Cabinets should be configured for the three-level cascading of the RXU chain.
If you find the configuration error of a frequency band in a cell or BTS after the configuration is complete, you need to delete the cell or BTS and then add a cell or BTS for modifying a frequency band. The reason is that a frequency band cannot be modified in a configured cell or BTS.
BTS3012, BTS3012AE, BTS3012_II, DBS3900, BTS3900, BTS3900A, BTS3900B, and BTS3900E do not support that Muplex Mode is set to HALF.
The parameter Peer Port IP address index specifies the index of the valid IP address for a BSC port. The BSC supports the settings of multiple IP addresses under one Port No.. Peer Port IP address index maps the valid IP address of the BSC port. After the value of Peer Port IP address index is specified, the BSC IP Address in the IP Interface Board Parameter of BTS tab page is generated automatically and cannot be changed.
You can obtain the BTS Interface Board Bar Code by running the DSP BTSESN command.
The slot for adding a board must be consistent with the SFP port. SFP Port No. must be set to 3, 4, or 5. Among six CPRI ports on the GTMU, ports 3, 4, and 5 are used to connect the RF module; ports 0, 1, and 2 are used to connect the three CPRI ports on the WBBP.
Parameter |
Setting Description |
---|---|
Send Receive Mode |
Set this parameter according to the actual RF connections. For details, see Setting Antenna Attributes. |
Antenna Tributary 1 Tower-Top Amplifier Flag |
Set this parameter according to the actual configuration of the antenna. |
Antenna Tributary 1 Tower-Top Amplifier Attenuation Factor (dB) |
Set this parameter to TMA Gain-4. Obtain information on the "TMA gain" from the product specifications. |
For details about configuring the RXU chain and RF module in different cascading modes, see Adding the RXU Chain and RF Module (Star Topology), Adding the RXU Chain and RF Module (Chain Topology), or Adding the RXU Chain and RF Module (Ring Topology).
Physical Port on the GTMU |
Logical Port |
Connection Attributes |
Switch Port |
Description |
---|---|---|---|---|
CPRI_0 |
SFP_0 |
BBU |
3-5 |
Physical port specifies a CPRI port that connects to the WBBP. Logical port specifies a logical port that is bound to one of ports SFP_3, SFP_4, and SFP_5, thus achieving information exchange between the RF module and the WBBP. |
CPRI_1 |
SFP_1 |
|||
CPRI_2 |
SFP_2 |
For two cells, the values of at least one of the following parameters should be different: MCC, MNC, LAC, and CI.