ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the OML link is disconnected. |
2 | BoxNo | Number of the BSC Subrack where the OML link is disconnected. |
3 | SlotNo | Number of the BSC Slot where the OML link is disconnected. |
4 | Port NO. | Number of the E1 where the OML link is disconnected. |
5 | Site Name | Site Name |
6 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML LST STATSLDWIN |
The BSC sends handshake messages to the BTS periodically, trying to reestablish the connection.
Y=> The upper-layer equipment of the BTS is the BSC. Go to b.
N=> The upper-layer equipment of the BTS is the BTS. Go to d.
408 Automatic Loading and Activation of BTS TMU Version
20081 Loss of E1/T1 Signals (LOS)
20082 Loss of E1/T1 Frames (LOF)
20083 Remote E1/T1 Alarm (RAI)
20084 E1/T1 Alarm Indication Signal (AIS)
20085 Loss of E1/T1 Multiframes (LOM)
20087 High BER over the E1/T1 Link
20221 Loss of Clock on the Optical Port (RLOC)
20222 Loss of Signals on the Optical Port (RLOS)
20223 Loss of Received Signal Frames on the Optical Port (RLOF)
20224 Out-of-Synchronization of Received Signal Frames on the Optical Port (ROOF)
20226 Regenerator Section Signal Failure (RSF)
20227 Regenerator Section Signal Deteriorated (RSD)
20228 Multiplex Section Alarm Indication Signal (MAIS)
20229 Multiplex Section Remote Defect Indication (MRDI)
20230 Loopback on the Optical Port
20231 Administration Unit Alarm Indication Signal (AUAIS)
20232 Loss of Administration Unit Pointer (AULOP)
20233 Service Unequipped on the High-Order Path of the Optical Port (HPUNEQ)
20235 High-Order Path Signal Label Byte Mismatch (HPSLM)
20236 High-Order Path Signal Failure (HPSF)
20237 High-Order Path Signal Deteriorated (HPSD)
20238 Remote Defect Indication on the High-Order Path of the Optical Port (HPRDI)
20239 Loss of Tributary Unit Multi-frames (TULOM)
20240 Tributary Unit Alarm Indication Signal (TUAIS)
20241 Loss of Tributary Unit Pointer (TULOP)
20242 Service Unequipped on the Lower-Order Path of the Optical Port (LPUNEQ)
20244 Signal Flag Mismatch on the Low-Order Path of the Optical Port (LPSLM)
20245 Low-Order Path Remote Failure Indicaton (LPRFI)
20246 Low-Order Path Remote Defect Indication (LPRDI)
20247 Tributary Unit Type Mismatch (TUSIZEERR)
20248 Loss of Tributary Signals (LOS)
20249 Tributary Alarm Indication Signal (AIS)
20250 Loss of Tributary Frames (LOF)
20251 Remote Alarm Indication over the Tributary (RAI)
20254 Tributary Loopback Alarm
20977 Failure of High-Speed Communication Link on the Backplane of Service Boards
20980 Ethernet Port Band Width Change
20981 Ethernet Port Duplex Mode Change
Y => Any of the previous alarms is reported. Go to c.
N => The alarm is not reported. Go to 2.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
4102 TRX LAPD Link Interrupt Alarm or other associated alarms
4714 E1/T1 Local Alarm or Other Alarms Related to Transmission on the Abis Interface on the BTS Side.
Y => Any of the previous alarms is reported. Go to e.
N => The alarm is not reported. Go to 2.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => Go to 3.
N => Go to b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to c.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
Y=> The BTS is equipped with batteries. Go to b.
Y=> The BTS is not equipped with batteries. Go to d.
Y => Any of the previous alarms is reported. Go to c.
N => The alarm is not reported. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y=> The BTS experiences power failure. Go to e.
N=> The BTS does not experience power failure. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 5.
Y => Go to 6.
N => Go to 7.
panel.
Y => Remove the E1 cable from the E1 Signal Lightning-Protection Card panel. Go to b.
N => Go to 7.
Y=> The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 7.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.